website
 +86 22 66224148   jack@unionvalve.com

Доверьтесь качеству. Создавайте взаимовыгодные решения.
valve for Fire Protection

Fire Protection Valves for Reliable Fire-Water Systems

Request Fire Protection Valve Selection
Fire-Water System Applications

Where Fire Protection Valves Are Used

Explore typical valve locations and product options across fire pump, sprinkler, hydrant and fire-water distribution systems.

Fire Pump Rooms

Valve solutions for dependable isolation, non-return protection and equipment connection around fire pump installations.

Typical line positions

Pump suction · Pump discharge · Bypass · Test lines

Recommended products
  • Gate Valves
  • Check Valves
  • Butterfly Valves
  • Flanges

Sprinkler Systems

Isolation and directional flow solutions for wet, dry and pre-action sprinkler system pipework.

Typical line positions

Main supply · Zone isolation · Risers · Test and drain branches

Recommended products
  • Butterfly Valves
  • Gate Valves
  • Check Valves
  • Flanges

Hydrant and Standpipe Systems

Reliable shut-off and non-return protection for hydrants, standpipes and zoned fire-water supply networks.

Typical line positions

Building inlets · Standpipe risers · Zone branches · Hydrant mains

Recommended products
  • Gate Valves
  • Butterfly Valves
  • Check Valves
  • Flanges

Fire-Water Storage and Distribution

Valve and connection solutions for controlling fire water between storage facilities and distribution networks.

Typical line positions

Tank outlets · Reservoir lines · Ring mains · Building supply lines

Recommended products
  • Butterfly Valves
  • Gate Valves
  • Check Valves
  • Flanges
Recommended Products for Fire Protection Systems

Product selection should be based on the system location, pipe size, design pressure, connection type, operating method, required approvals and applicable fire-protection standards.

Butterfly Valves

Compact shut-off valves for fire-water mains and sectional isolation points. Their short face-to-face dimension makes them suitable for large pipe sizes and installations with limited space.

Duty: On/off isolation
Connections: Wafer · Lug · Grooved · Double flanged
Typical locations: Fire-water mains · Sprinkler risers · Pump discharge lines
Selection: Size · Pressure · Connection · Operation

Explore Butterfly Valves
gate valve

Gate Valves

Full-bore isolation valves for locations where unrestricted flow and low pressure loss are important. They are normally operated fully open or fully closed.

Duty: Main pipeline isolation
Designs: Resilient seated · NRS · OS&Y
Typical locations: Pump suction lines · Hydrant mains · Standpipes · Tank outlets
Selection: Size · Pressure · Stem design · Connection

Explore Gate Valves
check valve

Check Valves

Automatic non-return valves that prevent water from flowing back through pumps and supply pipelines. Closing performance should be matched to the flow velocity and potential surge conditions.

Duty: Reverse-flow prevention
Types: Swing · Dual plate · Silent check
Typical locations: Pump discharge lines · Fire-water supply lines · Zoned networks
Selection: Flow velocity · Orientation · Closing response · Installation space

Explore Check Valves

Flanges

Detachable pipe connections used to join valves, pumps and fire-water pipelines. Flange dimensions and ratings must match the connected equipment, gasket and bolting arrangement.

Duty: Valve and equipment connection
Typical locations: Pump connections · Valve connections · Risers · Fire-water mains
Selection: Standard · Size · Pressure rating · Facing · Material

Explore Flanges
Product Selection Guide

How to Choose Fire Protection Valves and Flanges

Start with the required function and installation point, then confirm the size, pressure rating, connection, materials, operation and project approval requirements.

1

Choose the Product by Function and Location

If the project requires Choose Typical locations
Full-bore isolation with minimal flow restriction Gate Valve Pump suction and discharge lines, hydrant mains, standpipes and tank outlets
Compact isolation where installation space is limited Butterfly Valve Large-diameter mains, sprinkler risers, ring mains and sectional isolation points
Automatic prevention of reverse flow Check Valve Fire pump discharge and fire-water supply lines
A detachable connection between valves, pumps and pipelines Flange Pump connections, valve connections, risers and fire-water mains
2

Confirm the Product Configuration

Nominal size

Match the product to the specified pipeline size.

Pressure rating

Confirm the design pressure and possible surge conditions.

Connection

Confirm flanged, wafer, lug or grooved connection, subject to product type.

Body and seat materials

Match the water quality, temperature, corrosion conditions and project specification.

Operation

Confirm handwheel, lever, gearbox or actuator requirements.

Installation space

Check accessibility, orientation and maintenance clearance.

Standards

Follow the contract, drawings and technical specification.

Approval

Verify required approval for the specific product and model.

Final selection must be confirmed against the project specification. Any required approval should be verified for the specific product type and model offered.

Fire Protection Valves FAQs

Where is a check valve installed in a fire pump system?

It is normally installed on the pump discharge line to prevent water from flowing back through the pump.

Are UL Listed or FM Approved configurations available?

Availability depends on the valve model, size and configuration. Please specify the required approval so it can be confirmed before quotation.

Which valve connections are available for fire-water pipelines?

Common options include flanged, wafer, lug and grooved connections, depending on the valve type and pipework.