website
 +86 22 66224148   jack@unionvalve.com

Доверьтесь качеству. Создавайте взаимовыгодные решения.
valve for Wastewater

Wastewater Valves for Collection and Treatment Systems

Request Valve Selection Support

WASTEWATER PROCESS

Where Valves Are Used in a Wastewater System

Valve requirements change as wastewater moves from collection and pumping through treatment and final discharge. Selection should consider the medium, solids content, pressure, line size and operating duty at each stage.

  1. Collection Network

    Pipeline isolation for inspection, maintenance and network sectioning.

    Recommended valve types

    Confirm selection against debris and solids content.

  2. Preliminary & Primary Treatment

    Isolation of screened influent, outlet and settling-tank pipelines.

    Recommended valve types

    *After reviewing solids content and service conditions.

Recommended Valve Types for Wastewater Systems

Valve type should be selected around the process stage, medium, solids content, line size, pressure and operating requirements.

butterfly valve

Butterfly Valves

Compact valve options for large-diameter lines, limited installation space, and suitable isolation or throttling duties. Media conditions must be reviewed before selection.

Connections: Wafer · Lug · Double flanged
Actuation: Manual · Pneumatic · Electric
Typical service: Screened wastewater · Process water · Aeration air · Effluent

View Butterfly Valves
gate valve

Resilient Seated Gate Valves

Full-open or full-closed isolation for collection, pumping and treatment pipelines. Suitability should be reviewed where solids, fibres or sediment may accumulate.

Applicable standards: BS 5163 · EN 1074 · AWWA C509/C515
Options: NRS · OS&Y
Typical duty: Pipeline and equipment isolation

View Gate Valves
check valve

Check Valves

Used on pump discharge lines and other locations requiring reverse-flow prevention. The specific design should reflect solids passage, surge risk, orientation and flow velocity.

Types: Swing · Ball · Dual plate · Silent
Duty: Pump discharge · Backflow prevention
Selection: Closing behavior · Orientation · Flow conditions

View Check Valves
ball valve

Ball Valves

Compact on/off isolation for smaller drain, sampling, auxiliary and chemical-dosing lines. Body, seat and seal materials must be checked against the actual medium.

Duty: On/off isolation
Typical lines: Drain · Sampling · Auxiliary · Dosing
Selection: Medium compatibility · Pressure · Temperature

View Ball Valves
Valve Selection

How to Select Valves for Wastewater Service

Wastewater valves should be selected according to the actual service conditions. Review the medium, solids content, valve function, pipeline data, materials and operating method before specifying a valve.

01

Medium and Solids Content

Identify whether the service involves raw sewage, screened wastewater, process water, sludge, chemical wastewater or treated effluent.

Fibres, grit and suspended solids can affect the valve flow path, seat and closing performance.

High-solids and unscreened services require additional review.
02

Required Valve Function

Match the valve type to the required operating duty.

  • Isolation: Gate or butterfly valve
  • Backflow prevention: Check valve
  • Flow regulation: Suitable control valve and actuator
  • Auxiliary lines: Ball valve for suitable drain, sampling or dosing duties
03

Pipeline Data

Confirm the main pipeline and design parameters.

  • Nominal diameter
  • Operating and design pressure
  • Operating temperature
  • Flange or connection standard
  • Available installation space
Butterfly valves may offer a compact option for large-diameter pipelines, subject to the actual service conditions.
04

Body, Seat and Wetted Materials

Review the body, disc or wedge, shaft, seat and sealing materials against the wastewater composition and temperature.

  • Cast iron or ductile iron
  • Carbon steel or stainless steel
  • EPDM, NBR, FKM or PTFE seats
Material availability depends on the valve type, size and pressure rating.
05

Manual or Automated Operation

Select the operating method according to operating frequency, required closing time and the plant control system.

  • Hand lever
  • Gear operator
  • Pneumatic actuator
  • Electric actuator
06

Installation Conditions

Confirm the installation orientation, flow direction, maintenance space and surrounding environment.

  • Horizontal or vertical installation
  • Flow direction and available space
  • Indoor, outdoor or submerged environment
  • Access for operation and maintenance
For check valves, also review flow velocity, closing behaviour and possible surge conditions.

Have a Valve List or Project Specification?

Send us the medium, solids content, valve size, pressure, temperature, connection standard and actuation requirements. We will review the application before recommending a suitable valve configuration.

Wastewater Valve FAQs

Which valve is suitable for a wastewater pump discharge?

A check valve is commonly used to prevent reverse flow, with a gate or butterfly valve for isolation. Selection should consider flow velocity, solids and surge risk.

Can butterfly valves handle wastewater containing solids?

Butterfly valves can handle suitable screened wastewater and process water. Unscreened sewage or high-solids service requires additional review of the valve design and operating conditions.

What valve materials are used for corrosive wastewater?

Options may include coated ductile iron, carbon steel or stainless steel with EPDM, NBR, FKM or PTFE seats. Final selection depends on the wastewater chemistry, concentration and temperature.

How do I select a valve for sludge service?

Review the solids concentration, particle size, fibres, abrasiveness and chemical composition. The flow path and seat design must be checked for blockage, wear and sediment buildup.

Особые инструкции для продавца

Что вы ищете?

Chat with us