+86 22 66224148   jack@unionvalve.com

Trust in quality. Create win-win situations.

Check Valve Maintenance and Troubleshooting Guide

Check valves are designed to allow media to flow in one direction and prevent backflow, protecting pumps, pipelines, and other equipment in water supply, wastewater treatment, and industrial piping systems.

Over time, internal components may wear or corrode, while dirt and debris can gradually build up inside the valve. If components such as the disc, spring, or sealing surfaces become damaged, the valve may fail to close properly, leading to leakage or increased flow resistance.

Regular maintenance helps identify these problems early and keeps the check valve operating properly. This article covers the main inspection points, cleaning and maintenance procedures, and how to determine whether a check valve needs repair or replacement.

check-valve

Why Is Regular Check Valve Maintenance Important?

Check valves open and close automatically in response to the direction of flow. When internal components wear or deposits build up inside the valve, disc movement and sealing performance can be affected.

Regular maintenance helps to:

  • Prevent backflow and leakage
  • Reduce water hammer and pressure surges
  • Maintain proper flow performance
  • Extend service life and reduce maintenance costs

Common Check Valve Problems and How to Fix Them

The most common check valve problems include leakage, chattering, slamming, disc sticking, and excessive pressure drop. The symptoms, possible causes, and recommended solutions for each problem are outlined below.

1. Check Valve Leakage

Symptoms

Backflow continues even after the check valve has closed, indicating a possible failure of the internal sealing surfaces. External leakage may also occur around the valve body joints or flange connections.

Possible Causes

  • Debris trapped between the disc and valve seat.
  • Worn, scratched, or damaged sealing surfaces.
  • Corrosion or erosion of the disc or valve seat.
    Damaged gaskets or improperly tightened valve body connections.

How to Fix It

  • Check for debris trapped between the disc and valve seat.
  • Remove deposits from the sealing surfaces.
  • Inspect the sealing surfaces for scratches, corrosion, and wear.
  • Replace damaged sealing components or connection gaskets as necessary.
  • Perform the required sealing tests after reassembly.

Internal check valve components showing disc wear, corrosion, and deposits

2. Check Valve Chattering and Vibration

Symptoms

The disc moves rapidly back and forth during operation, producing repeated knocking or rattling noises. The valve body and connected pipeline may also vibrate.

Possible Causes

  • Flow velocity is too low or unstable to keep the disc in a steady open position.
  • The valve is oversized for the actual flow rate.
  • Frequent flow fluctuations or turbulence affect disc movement.
  • Internal components, such as hinge pins or springs, are worn or loose.

How to Fix It

  • Check whether the actual flow rate and velocity meet the valve's operating requirements.
  • Confirm that the valve size is suitable for the system.
  • Inspect the disc, hinge assembly, and spring.
  • Replace worn or damaged internal components.

If the existing valve cannot handle the actual flow conditions, consider replacing it with a check valve of a more suitable design.

3. Check Valve Slamming and Water Hammer

Symptoms

A loud banging noise occurs when the valve closes, sometimes accompanied by sudden pressure fluctuations or vibrations in the pipeline. In severe cases, repeated slamming can damage internal components and pipeline connections.

Possible Causes

  • Reverse flow develops before the disc reaches the fully closed position.
  • The disc closes too slowly after forward flow stops.
  • The valve design is not suitable for the actual flow conditions in the system.
  • Sudden pump shutdown or rapid changes in flow rate cause pressure surges.

How to Fix It

  • Inspect the disc and closing mechanism to ensure they move freely.
  • Check the system flow velocity and pump operating conditions.
  • Where operating conditions allow, consider using a spring-assisted or slow-closing check valve.
  • Make sure the valve's closing characteristics are suitable for the actual application.
  • If water hammer is severe, inspect the entire piping system and install appropriate protective measures.

If a check valve repeatedly experiences slamming, pay particular attention to its closing speed, system flow velocity, and pump operating conditions.

For applications requiring spring-assisted closure, a Dual Plate Check Valve may be a suitable option. For applications requiring faster closure to reduce disc slamming, consider a Silent Check Valve.

4. Check Valve Stuck in the Open or Closed Position

Symptoms

The disc cannot move freely. If stuck in the open position, the valve may fail to prevent backflow. If stuck in the closed position, it may restrict or completely block forward flow.

Possible Causes

  • Debris or foreign objects obstruct disc movement.
  • Corrosion or deposits build up on internal components.
  • Hinge pins, valve shafts, or guide components are worn or damaged.
  • The spring is broken, deformed, or has lost its elasticity.

How to Fix It

  • Isolate the valve and release all pipeline pressure.
  • Disassemble the valve according to the manufacturer's maintenance instructions.
  • Remove internal debris and deposits.
  • Inspect the disc, hinge pins, valve shaft, guide components, and spring.
  • Replace damaged parts and check that the disc moves freely before reassembling the valve.

Diagram of Check Valve Corrosion

5. Excessive Pressure Drop Across the Check Valve

Symptoms

Common signs include lower-than-expected downstream pressure, reduced system flow rate, or increased pumping energy consumption.

Possible Causes

  • The valve size does not match the actual flow requirements.
  • Insufficient flow or mechanical obstruction prevents the disc from opening fully.
  • Deposits or foreign objects restrict the flow passage.
  • The selected valve design has higher flow resistance than the system can accommodate.

Common check valve problems and solutions, including leakage, chattering, slamming, stuck discs, and excessive pressure drop

How to Clean and Maintain a Check Valve

For check valves designed for disassembly and maintenance, the following general maintenance steps can be used as a guide.

1. Isolate the Valve and Release Pipeline Pressure
Isolate the valve, make sure the pipeline is completely depressurized, and drain any remaining media from the valve before starting disassembly.

2. Clean the Internal Components
Clean the disc, valve seat, and internal flow passages to remove dirt, scale, and deposits that may affect disc movement or sealing performance. Make sure the cleaning tools and agents are compatible with the valve materials.

3. Inspect and Maintain Moving Parts
Check the disc, valve seat, hinge pins, valve shaft, and spring (if fitted) for wear, corrosion, or damage. Replace damaged parts promptly and apply suitable lubricant only to the areas recommended by the manufacturer.

4. Reassemble and Test the Valve
Reassemble the valve according to the manufacturer's instructions. Before putting it back into service, carry out the required pressure or functional tests.

Keep maintenance records of inspection results, replaced parts, and recurring problems. These records help track valve condition and plan future maintenance.

When Should a Check Valve Be Replaced?

A check valve does not always need to be replaced entirely when a problem occurs. In some cases, normal operation can be restored by replacing the disc, spring, sealing components, or other damaged parts.

The following situations should be considered when deciding whether to replace the entire check valve:

Condition

Recommendation

Severe Body Damage

If the valve body has severe cracks, deformation, or corrosion damage that compromises its pressure-bearing capacity, and safe operation cannot be restored through approved repair methods, the valve should be considered for replacement.

Extensive Internal Wear or Corrosion

If the disc, valve seat, or other critical internal components are severely worn or corroded, and replacing individual parts cannot restore normal performance, full valve replacement should be evaluated.

Repeated Operational Problems

If the valve continues to experience leakage, sticking, or abnormal vibration after repeated repairs, reassess whether its design, size, and operating conditions are suitable for the application.

Repair Is No Longer Economical

If repair costs, downtime losses, and future maintenance expenses are significantly higher than the cost of replacement, installing a new valve may be the more cost-effective option.

Titling-check-valve-4

If your existing check valve repeatedly experiences leakage, vibration, slamming, or excessive pressure drop, it may be necessary to reassess not only the valve itself but also its type, size, and actual operating conditions.

Union Valve offers a range of check valves for water supply, wastewater treatment, and industrial pipeline systems, including swing check valves, dual plate check valves, and silent check valves.

If you are looking to purchase check valves, please provide your required valve size, pressure rating, connection standard, media, and operating conditions. Our team can help you select a suitable valve based on your application requirements and provide product drawings and a quotation.

 

Related Articles:

About the Author
Serena Zhang
Serena Zhang
Sales Manager · Tianjin Union Valve Co., Ltd
With 4 years of valve export experience and dedicated service, Serena ensures a smooth and reliable order process. Quick replies 24/7. Welcome your inquiries!

Leave a comment

Please note, comments must be approved before they are published

}